LW36-126 type outdoor self-energizing high-voltage sulfur hexafluoride circuit breaker is suitable for AC 50Hz , 126kV power system, it is the control and protection equipment of the power system, and it can also be used as the contact circuit breaker.
The circuit breaker takes SF6 gas as insulation and arc extinguishing medium, adopts the principle of self-energizing arc extinguishing, and is equipped with spring-operated mechanism, which is characterized by strong breaking capacity, small operating work and high reliability.
Product structure characteristics
The circuit breaker adopts three-phase ceramic bottle pillar structure, designed for outdoor, three-phase with a SRCT36-C spring-operated mechanism, centered arrangement, three linked, so the appearance of novel circuit breaker to SF
Novel view of the circuit breaker to SF6 gas as insulation and arc extinguishing medium, operation of the circuit breaker three-pole SF6 gas should be connected, and the use of pointer-type density relay to monitor its pressure and density.
The pressure and density are monitored by pointer-type density relay. Due to the use of self-energized arc extinguishing principle and optimized design in the circuit breaker movement system, it improves the mechanical efficiency and reduces the operating power to a limited extent.”
Use of environmental conditions normal use of environmental conditions in line with the provisions of GB/T11022-1999 “high-voltage switchgear and control equipment standards for the common technical requirements,” the
That is :
1. Ambient temperature -40oC~+40oC; 2.
2. Altitude of not more than 3000m.
3. wind speed of not more than 34m/s; 4. daily temperature difference of not more than 25%.
4. daily temperature difference of not more than 25oC;”
5. sunlight intensity Not more than 0.1w/cm;
6. monthly average relative humidity not greater than 90%;”
7. Seismic acceleration Horizontal not more than 0.2g, vertical not more than 0.1g
8. Thickness of ice cover not more than 10mm.
9. The degree of air filth does not exceed GB5582 in the IV level;
10. Installation occasions outdoor.
Welded elbows in stainless steel pipe fittings can cause corrosion when used incorrectly. After corrosion occurs in welded stainless steel elbows, the pipe wall of t...
Thin-walled elbows in stainless steel pipe fittings are a common pipe connection component. They are generally sanitary grade. The grooves are generally flat and hav...
Flanged joints in stainless steel pipe fittings are a kind of connecting material commonly used in the construction and engineering fields. It uses a stamping proces...
There are also many ways to process stainless steel flanges. Many of them still belong to the category of mechanical processing, and the most commonly used methods a...