Tel: +86 13706784523(Whatsapp)/

Email: amy@putai-electric.com /

GW4-40.5 Outdoor High-voltage Disconnector

> Hot products

Outdoor pole mounted SF6 insulated load switch

Click to Learn More

XGN15-12 type unit type AC metal-enclosed ring network switchgear

XGN15-12 type unit type AC metal-enclosed ring network switchgear

Click to Learn More

KYN28-12 metal armored move-open type enclosed switchgear

KYN28-12 metal armored move-open type enclosed switchgear

Click to Learn More

GW4-40.5 Outdoor High-voltage Disconnector
GW4-40.5 Outdoor High-voltage Disconnector

Name:Disconnect switch

FOB Port:Ningbo/Shanghai/Yiwu/Guangzhou/Shenzhen

Terms of Payment:T/T

Product Description

The disconnecting switch adopts double-column centre-open, contact-transferring structure, which has the ability to clean the contacts automatically and improves the contact reliability;

The contact fingers are made of new materials with high strength, high conductivity and high elasticity. Relying on the elasticity of the contact fingers themselves to clamp the contacts, avoiding the current spring corrosion, heat annealing and contact caused by the reduction of clamping force, contact resistance.Avoiding the vicious circle caused by spring corrosion and heat annealing, which reduces the clamping force, increases the contact resistance and intensifies the contact heating.

Name Unit   Parameter
Rated voltage     kV   40.5    72.5      126 
Imin frequency withstand voltage, voltage   Pair grounding kV   95    140      230 
Rated insulation level Disconnect kV   115    160      245 
Lightning impulse withstand voltage (peak)) Pair grounding kV   185    325      550 
Disconnect kV   215    375      630 
Rated frequency   Hz       50       
Rated current     A 400  6301000  1250  1600  2000  3150   4000 
Rated short-time withstand current     kA 20  2031.5  31.5  40  40  50   50 
Rated peak withstand current     kA 40  5063  80  100  100   125   125 
Rated short-circuit duration main/ground blade     S       4/2      
Rated terminal mechanical load   Horizontal longitudinal load   N   750       1000 
  Horizontal Mode Load   N   500      75   
  Vertical force   N   750      1000   
Creepage distance     mm   1025-1250   1800-2 250  3150-  3900 
Mechanical life     time     200     
Manually operated mechanism   Without grounding           CS11( F)  
  Single grounding           CS8-6D(F)
  Single grounding     刀CS14G(F),地刀CS11(F)
   Control circuit voltage   V     AC220,DC    110.DC220
Motor actuator   Model         CJ6      
   Motor Voltage   V      AC380
  Control circuit voltage   V     AC220,AC380,DC220
  Opening and closing time   s            
 Product weight   Ungrounded   kg   360    500    70   0 
  Single grounding   kg   410    600    80   0 
  Double grounding   kg   460    700    90   0 

Message

Related products

ZN85-40.5 series indoor high voltage vacuum circuit breaker

ZN85-40.5 series indoor high voltage vacuum circuit breaker

Click to Learn More

LW38-40.5(G)-CJ Elevated Porcelain Pillar Outdoor High Voltage AC Sulfur Hexafluoride Circuit Breakers

LW38-40.5(G)-CJ Elevated Porcelain Pillar Outdoor High Voltage AC Sulfur Hexafluoride Circuit Breakers

Click to Learn More

LW38-126 outdoor self-energizing high-voltage sulfur hexafluoride circuit breaker

Click to Learn More

Related News

> Preheating treatment and cooling process of welded elbows in stainless steel pipe fittings

Welded elbows in stainless steel pipe fittings can cause corrosion when used incorrectly. After corrosion occurs in welded stainless steel elbows, the pipe wall of t...

> Bending performance and characteristics of thin-walled flat elbows in stainless steel pipe fittings

Thin-walled elbows in stainless steel pipe fittings are a common pipe connection component. They are generally sanitary grade. The grooves are generally flat and hav...

> The waterproof function and role of flanging in stainless steel pipe fittings in pipeline applications

Flanged joints in stainless steel pipe fittings are a kind of connecting material commonly used in the construction and engineering fields. It uses a stamping proces...

> Processing methods for stainless steel flanges and various rust removal methods for pipe fitting elbows

There are also many ways to process stainless steel flanges. Many of them still belong to the category of mechanical processing, and the most commonly used methods a...

GET A QUOTE

+86

+86 +86 13706784523(Whatsapp)

amy@putai-electric.com

Get in Touch

Captcha Code
×